AN ANALYTICAL AND EXPERIMENTAL STUDY ON REINFORCED CONCRETE BEAM WITH CARBON FIBER FABRIC WRAP

Abhijith S1* and Senthil Kumar G2

1M. Tech, structural engineering, Department of civil engineering, SRM university, kattankulathur, Chennai, Tamil Nadu, India

2Professor, Civil Engineering Department, SRM University, Chennai, Tamil Nadu, India

*Corresponding Author:
Abhijith S
E-mail: abhijithsureshkarnikaram@gmail. com; senthilkumar. go@ktr. srmuniv. ac. in

Received 11 July, 2017; Accepted 24 October, 2017

Visit for more related articles at Journal of Industrial Pollution Control

Abstract

Retrofitting materials like aluminum bars, steel laminates and glass fiber compounds has been used in the construction field for many decades. Carbon fiber compounds are the recent addition to the retrofitting materials. This study is a comparison of flexural and shear strength of a retrofitted beams with conventional beam. It also compares the experimental results with the analytical results. Analysis is done using the software ANSYS workbench. Carbon fiber fabric wraps are used for retrofitting test beams. Epoxy resin is used to bind the fabric to the beam in u – shaped wraps which binds the flexural face and the web of the beam. Total number of 4 beams of size (1500 × 200 × 250) mm including conventional beam is used for the experimental tests ( Two point loading). Difference in ultimate load, criticalload,flexural strength and shear strength are observed in experimental tests, and are being compare with analytical results. The beams were wrapped with five layers of carbon fiber fabric strips of different widths, 300 mm, 250 mm and 200 mm respectively. The highest flexural strength was observed in the two point load testing of beam retrofitted with 300 mm wide strips (BU30).

Keywords

Critical load, Ultimate load, Flexural load, Shear stress, Deflection

Introduction

1. To compare the difference in critical load, ultimate load and flexural strength of beam specimens retrofitted with carbon fiber fabric wrap (Bu30,Bu25, Bu20) at different widths, i.e., 30 cm, 25 cm and 20 cm respectively.

2. To compare the experimental values of retrofitted beam specimens with conventional beam specimen’s (Bconv) test results.

3. To analyze the specimens tested experimentally in ANSYS software and to compare the analytical results with the experimental results.

4. To find the beam specimen with highest flexural strength and to compare its analytical values with the experimental values.

5. To check the shear stress distribution in the specimens using ANSYS software and find the maximum shear values of the specimens and the points at which shear concentration is higher.

Methodology

Use of carbon fiber based retrofitting sheets or mats have been in use for the past decade. Even though sufficient studies has to be carried out to optimize the cost involved in retrofitting since carbon fiber compounds are expensive. Carbon fiber fabric is abi- directional anisotropic compound. Retrofitting using carbon fiber fabric mat requires proper binding using epoxy resins. Epoxy resin plays a key role in the experiment by avoiding debonding failure during the experimental tests. The carbon fiber fabric as compared to carbon fiber woven sheets are very thin loosely arranged, minimum of five layer is required for adequate strength (Murali and Pannirselvam, 2011; Norris, et al., 1997; Antonopoulos and Triantafillou, 2002). In this study, carbon fiber fabric mats having three different widths [30, 25, 20] cm are u – wrapped constant intermediate gap of 10 cm to the beam specimens (Figure 1).

icontrolpollution-Methodology-flow

Figure 1: Methodology flow chart.

Mix Design

The specified strength of the concrete is 35 mpa in 28 days. The specific gravity of cement, coarse aggregate and fine aggregate are 3.15, 2.884 and 2.29 respectively. Grade of the cement used for the casting is opc 53. The water cement ratio adopted is 0.45. The mix proportion of the concrete has been obtained by the code [IS 10262-1982]. The mix proportion obtained has been showed in Table 1.

Water (Liter) Cement (kg) Fine aggregate (kg) Coarse aggregate (kg)
186 132 232.32 410.83
1.40 1 1.76 3.17

Table 1: Mix proportion

The compression test of the concrete at 28 days has been carried out to check the average compressive strength of the concrete. The values obtained is as tabulated in the Table 2 and (Figure 2). From the test results, the average compressive strength of the concrete is found to be 34.56 N/mm2.

icontrolpollution-cube-specimen

Figure 2: Compression test of cube specimen CC2.

S. No Mould Number Fresh Concrete Density in Kg Hardened Concrete Density in Kg Compressive Strength In N/Mm2 Avg.
Compressive Strength in N/Mm2
1 CC 1 2666.66 2400 34.6   34.56
2     CC 2 2577.77 2429.63 36.1
3     CC 3 2607.41 2459.25 33

Table 2: Compression test results of concrete cubes (150 × 150) mm

Experimental Study

Total number of four beam specimens has been casted for the experimental studies. Beam specimens casted have been cured for 28 days before testing. Size of the beams are 1500 mm × 200 mm × 250 mm. Nomenclature of the beam specimens are as given in Table 3. Excellent bonding between the carbon fiber fabric mat and the surface of the beam specimen is required for the efficient increase in flexural strength of the specimen. Epoxyresin provides the adequate bonding strength to avoid debonding failure and the carbon fiber fabric mat act uniformly as the specimen under the loading condition (Figures 3 and 4).

icontrolpollution-Cracks-formed

Figure 3: Cracks formed during the test of Bconv.

icontrolpollution-Test-setup

Figure 4: Test setup of BU25.

Bconv

Conventional beam

Bu20

Beam wrapped with 200mm wide strips at 100mm spacing

Bu25

Beam wrapped with 250mm wide strips at 100mm spacing

Bu30

Beam wrapped with 300mm wide strips at 100mm spacing

Table 3: Nomenclature of test beam specimens

Testing of Beam Specimens

All the beam specimens are being tested under two point loading condition. The conventional beam (Bconv) is tested first to find out the critical and ultimate loads. The flexural strength is found out using the formula,

image (1)

Where σ is the flexural stress or the bending stress of the beam; F is the ultimate load exerted on the beam specimen; L is the effective length of the beam specimen; b is the breadth of the beam; d is the depth of the beam (Figure 5).

icontrolpollution-Test

Figure 5: Test setup of BU30.

Similarly, the retrofitted test beams, Bu30, Bu25, Bu20 are also tested respectively. The experimental test results of each beams which has been recorded are tabulated in Table 4. which is as follows:

Specimen Critical load (KN) Ultimate load (KN)   Flexural
stress(KN/mm2)
Bconv 56 112 0.011
Bu20 64 144 0.014
Bu25 68 152 0.015
Bu30 76 168 0.017

Table 4: Experimental test results

Experimental Test Results

The experimental test results shows that there is an increase in the flexural stress or the bending stress as the width of the carbon fiber fabric wrap is increased. The load bearing capacity of the beam is increased as the width of the wrapping is increased. As compared with the ultimate load of conventional beam, the percentage increase in BU20, BU25 and BU30 are 28.57%, 35.71% and 50% respectively. Similarly, as compared with the conventional beam, the percentage increase in flexural strength of BU20, BU25 and BU30 are 27.27%, 36. 36% and 54.55%.

The graphical representation of difference in ultimate load and flexural strength in test beams are showed in (Figure 6 and Figure 7) respectively (Yoganathan and Mahendran, 2014; Kharatmol, et al., 2014; Yasmeen, 2010).

icontrolpollution-Ultimate-load-chart

Figure 6: Ultimate load chart of specimens.

icontrolpollution-Flexural-strength

Figure 7: Flexural strength of specimens.

The deflection at the right, left and the center portion of the beam specimen is during two point loading is found out and tabulated using strain gauges. Since the procedure is a progressive loading the range of loading was adopted to be 4 KN (Venkatesha, et al., 2012). The load vs deflection graph is showed in the following figures (Figures 8-11).

icontrolpollution-deflection-graph

Figure 8: Load vs. deflection graph of Bconv.

icontrolpollution-deflection-graph

Figure 9: Load vs. deflection graph of BU20.

icontrolpollution-Load-deflection

Figure 10: Load vs. deflection graph of BU25.

icontrolpollution-graph-BU30

Figure 11: Load vs. deflection graph of BU30.

From the experimental test results, among the retrofitted test beams BU30 has the maximum deflection when BU20 has the minimum deflection. BU30 has the maximum ultimate load value while BU20 has the minimum ultimate load value (Table 5).

Specimen Ultimate load (KN) Maximum deflection (mm)
Bconv 112 9.92
BU20 144 8.88
BU25 152 9.18
BU30 168 9.20

Table 5: Corresponding deflection under respective ultimate load of test beams

Analytical Study

The analytical part mainly consist of three stages, they are modeling, meshing and analysis. The modeling of the beam is carries out by creating the exact model of the test specimens. Meshing is the part where the choice of fine meshing or coarse meshing is made. This study is carried out under fine mesh condition. As the mesh gets finer the time taken for the analysis also increases.

Exact conditions where the experiments has been carried out is stimulated in ANSYS Workbench. The loads, Loading distances and support distances are provided exactly as the experimental setup. The physical and mechanical properties of the materials such as concrete, steel and carbon fiber is provided to the models.

Analytical Results of Specimens Loaded Under Ultimate Load of Conventional Beam

Analysis is done in two stages. First, by providing the ultimate load of conventional beam to the retrofitted beam in order to study the change in deformation and equivalent shear value in retrofitted beamsunder the ultimate load value condition of conventional beam. The analytical results under this condition is provided in Table 6.

Specimen Load(KN) Total deformation (mm) Equivalent stress (mpa)
Bconv 112 0.662 113.56
BU20 112 0.5209 110.34
BU25 112 0.4955 329.63
BU30 112 0.6095 105.52

Table 6: Change in deformation and equivalent shear value in retrofitted beams under the ultimate load value condition of conventional beam

As the results shows, the least deformation is showed by BU20 among retrofitted beam specimens as the maximum deformation is observed in BU30. The equivalent shear stress value is highest in BU25 as it is least in BU20 (Figures 12-16).

icontrolpollution-under-loading

Figure 12: Bconv under loading.

icontrolpollution-conventional-beam

Figure 13: BU20 under ultimate load of conventional beam.

icontrolpollution-ultimate-load

Figure 14: Bu25 under ultimate load of conventional beam.

icontrolpollution-under-ultimate

Figure 15: BU30 under ultimate load of conventional beam.

icontrolpollution-loading

Figure 16: BU20 under loading.

Analytical Test Results of Specimens Tested Under Respective Ultimate Loads

The second stage of analysis is that the specimens are analyzed using the experimental values of their own. The results thus obtained has been tabulated in Table 7.

Specimen Load (KN) Total Deformation (mm) Equivalent stress(mpa)
Bconv 112 0.662 113.56
BU20 114 0.669 142.5
Bu25 152 0.672 447.36
BU30 168 0.914 158.29

Table 7: Analytical test results of specimens tested under respective ultimate loads

Here the least deformation among retrofitted test beams was observed in BU20 when the maximum deformation is found in BU30. The least equivalent shear among retrofitted test beams was observed in BU20 where the maximum equivalent stress was observed in Bu25 (Figure 17 and Figure 18).

icontrolpollution-loading

Figure 17: BU25 under loading.

icontrolpollution-BU30-under

Figure 18: BU30 under loading.

Conclusion

Based on the experimental and analytical results the following conclusions has been made.

• The total deformation was highest for BU30 both in experimental as well as analytical results. Thus the beam wrapped with 300 mm wide strips has the largest deflection among the three retrofitted beams.

• Beam wrapped with 300m wide strips has the maximum flexural value (0.017 KN/mm2). While the beam retrofitted with 20 mm wide strips has the least value for flexural stress (0.014 KN/mm2).

• The maximum equivalent stress value was observed in beam wrapped with 250 mm wide strips. While the least equivalent stress value was observed in beam retrofitted with 200 mm wide strips.

• The experimental values and the analytical values of deflectionhas slight variation. This might be caused by the quality of materials, quality of casting, errors occurred during testing.

• As compared with the ultimate load of conventional beam, the percentage increase in BU20, BU25 and BU30 are 28.57%, 35.71% and 50% respectively. Similarly, as compared with the conventional beam, the percentage increase in flexural strength of BU20, BU25 and BU30 are 27.27%, 36.36% and 54.55%. Thus the most effective mode of retrofitting is clearly with 30 cm wide strips at 100 mm spacing.

This results are and conclusion is based on the experimental as well as analytical study of 4 beams. The air bubble or the void formed between the beam and the wrap is a phenomenon which cause variation in test results. Exact and 100% efficient bonding is not practically possible. This will cause variation in analytical and experimental results. Experiments with more number of beams can be done with more number of wrapping and varied width.

References

  1. Antonopoulos, C.P. and Triantafillou, T.C. (2002). Analysis of FRP-Strengthened RC Beam-Column Joints. Journal of Composites of Construction. 6 : 41-51.
  2. Kharatmol, R., Pankaj, S., Rohit, T. and Raksha, J.K. (2014). Strengthening of Beams Using Carbon Fibre Reinforced Polymer. International Journal of Emerging Engineering Research and Technology. 2 : 119-125.
  3. Murali, G. and Pannirselvam, N. (2011). Flexural strengthening of reinforced concrete beams.
  4. Norris, T., Saadatmanesh, H. and Ehsani, M.R. (1997). Shear and Flexural Strengthening of R/C Beams with Carbon Fiber Sheets. ASCE Journal of Structural. 123 : 903-911.
  5. Using Fibre Reinforced Polymer Laminate: A review. APRN Journal of Engineering and Applied Science. 6 : 41-47.
  6. Venkatesha, K.V., Dinesh, S.V., Balaji Rao, K., Bharatkumar, B.H., Balasubramanian, S.R. and Nagesh R.I. (2012). Experimental investigation of reinforced concrete beams with and without CFRP wrapping. Slovak Journal of Civil Engineering. 20(3) : 15-26.
  7. Yasmeen, T.O. Structural Retrofitting of Reinforced Concrete Beams Using Carbon Fibre Reinforced Polymer. (2010). ISRN LUTVDG/TVSM. Lund university. 1-76.
  8. Yoganathan, K.R. and Mahendran, N. (2014). Retrofitting of Geopolymer Beam Using Carbon Fibre Mat. International Journal of Innovative Research in Science, Engineering and Technology. 3 : 1251-1257.